Overcurrent Releases Mtec DTV3 Electronic Releases Designed for protection of cables and distribution systems supplied by a transformer. Basic adjustments to tripping characteristics are made simple with rotary controls on the front panel. Rated overload current can be set from 40% to 100% of nominal current and the short-circuit trip current can also be modified. Optional thermal memory simulation delays reset after thermal overload to allow the system to return to a safe operating temperature. Three nominal current ratings are available for each frame size. All trip curves are featured in the downloadable PDF along with more detailed technical data. Mtec MTV8 Electronic Releases Designed for protection of cables, motors and distribution systems supplied by a transformer or generator set. Fine-tuning of all tripping characteristics is made simple with rotary controls on the front panel. Rated overload current can be set from 40% to 100% of nominal current. Short circuit trip current is fully adjustable and can be delayed by 50ms if required. In addition, the MTV8 series offers a choice of specially calibrated trip curves to protect motors and transformers. When motor characteristics are set, the device also protects against phase failure, tripping if one or two phases fail for longer than 4s. Optional thermal memory simulation delays reset after thermal overload to allow the system to return to a safe operating temperature. Three nominal current ratings are available for each frame size. All trip curves are featured in the downloadable PDF along with more detailed technical data. Mtec M001 Electronic Releases Provides completely customisable tripping characteristics for protection of virtually any distribution application. Tripping discrimination enables optimised integration with other protection devices in the system. Fine-tuning of all tripping characteristics is made simple with rotary controls on the front panel. Rated overload current can be set from 51% to 100% of nominal current and the short circuit trip current is fully adjustable. In addition, a time-delayed secondary trip current can be set (with optional constant I²t if required) for discrimination between the Mtec MCCB and other protection devices in the system. Optional thermal memory simulation delays reset after thermal overload to allow the system to return to a safe operating temperature. This release is only suitable for use with MtecBL1600S Switching Units and four nominal current ratings are available. For more detailed technical data please see the downloadable PDF. Trip curves. Mtec V001 Switch Disconnect Adaptors Can be fitted in place of an electronic release to allow the switching unit to be used as a switch disconnector. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||