MOTEC Motor Starter

Due to it's high breaking capacity and high current limitation, Motec provides optimum overload and short-circuit protection for one to three-phase electric motors up to 25A, 690V ac.

Also equipped with phase failure protection and ambient temperature compensation, plus a range of accessories, Motec can provide motor protection, switching, remote signalling, enclosures, locking and simple connection.

- Motor starters are used for overload and short-circuit protection of one to three-
  phase electric motors up to 25A, 690V AC
- For manual (ON/OFF) switching of motors by green/red push-buttons on the front of
  the device
- Padlockable actuation
- Short-circuit release fixed at 11-13xIe
- Adjustable thermal release setting via rotary control on the front of the device
- Integral phase failure protection and temperature compensation
- Motec + accessories = protection + switching + remote signalling + enclosure +
  locking + simple connection


Accessories
Techna's Motec range of motor protection has a full range of accessories.


Auxiliary Contact Blocks
Side mounting contact blocks (maximum two, one on each side of Motec), can indicate manual switch ON/OFF or tripped OFF due to fault condition.


Shunt Trips and Undervoltage Releases
Shunt trips are designed to trip Motec on coil excitation by a voltage of between 70% and 100% x Ue. Maximum excitation time of the shunt trip coil is 5 seconds as it is not designed for continuous load. If required, connect the shunt trip via a N/O contact of auxiliary terminal block, to ensure that shunt-trip is shunt off with Motec.

Undervoltage releases are for automatic shutdown and prevention of motor restart following mains failure.


IP41/IP55 Enclosure
With integral PE (N) terminal top/bottom for conductor size 0.75-4mm². Top/bottom knockouts for bushings.


Three Phase Busbars and Incoming Terminal Blocks
For fast and easy connection of 2 or 3 Motecs installed side by side. Connection from top or bottom of Motec. Busbar connection allows a gap for one auxiliary contact block between adjacent Motecs. Feed-in block does not prevent use of busbars. Maximum load current is 63A.


Push Button Membrane and Plastic Bushings
Push button membrane provides IP55 protection after installation and includes frame and transparent rubber membrane. Plastic bushings are installed by screwing into knockout holes and used for sealing and holding of inlet/outlet cables.


Emergency Stops and Padlock Frames
Emergency stops and padlocks are available.


Light Indication and Neutral Conductor Connector
Mounted in enclosure via front panel knockouts and available in red, green and white 230Vac and 400Vac, Indicator lights indicate the position of main Motec contacts. Neutral conductor connector installed to mirror PE (N) connector inside the enclosure.


Download more information on MOtec Motor Protection (PDF 492KB)
.
 

Techna MOTEC Motor Starter

 
       
    Techna MOTEC motor starter accessories  
       
    Techna MOTEC motor starter accessories  
       
         
 
Technical Data
Standards EN 60947
Number of poles 3
Rated current (A) 0.16 - 25
Rated voltage (V) 690
Rated frequency (Hz) 50
Mechanical endurance 100,000 operating cycles
Electrical endurance (≤16A) 100,000 operating cycles,
(20, 25A) 40,000 operating cycles
Max. operations/hour 30
Rated impulse withstand voltage (kV) 1.2/50μs, 6kV
Mounting DIN-rail : 35mm, surface mount : 2xM4
Degree of protection IP20, in enclosure : IP55
Connection 0.75-4; 2x(0.75-4)mm²
Ambient temperature -5 to 55°C
Temperature compensation range -5 to 40°C
Operating position any
Vibration resistance 1.5g
Resistance to mechanical shock 10g
     
         
 
 